User Contributed MET/CAL PROCEDURE ============================================================================= INSTRUMENT: Kyowa AC Cal Signal Sub DATE: 27-Aug-97 AUTHOR: User Contributed REVISION: ADJUSTMENT THRESHOLD: 70% NUMBER OF TESTS: 13 NUMBER OF LINES: 244 CONFIGURATION: Fluke 5700A CONFIGURATION: HP 34401A ============================================================================= STEP FSC RANGE NOMINAL TOLERANCE MOD1 MOD2 3 4 CON 1.001 HEAD { AC Calibration Signals } 1.002 DISP In the UUT FUNCTION group press the MAN button. 1.002 DISP In the UUT ENTRY keypad press .2, EXC. 1.002 DISP Press MAN in the UUT FUNCTION group. 1.003 DISP In the UUT FUNCTION group press CAL SET. 1.003 DISP In the UUT ENTRY keypad press SFT1, CALA, EXC, SFT1, AC, 1.003 DISP .2, EXC. 1.004 DISP Press CAL SET in the FUNCTION group. 1.005 5700 0.14142V 100H S 2W 1.006 IEEE [@34401]FUNC "VOLT:AC" 1.007 IEEE [@34401]VOLT:AC:RANG:AUTO ON[GTL] 1.008 DISP Adjust the UUT CH 1 GAIN control for a reading 1.008 DISP of 3.5353V. 1.009 DISP Press the CAL button 2 times. 1.010 IEEE [@34401]FUNC "VOLT:AC" 1.011 IEEE [@34401]READ?[I] 1.012 ACC .2000V 0.2312% 1.013 MATH MEM = MEM / 3.535533906 1.014 MATH MEM = .2 * MEM 1.015 MEMC V 1% 2.001 DISP Press the CAL button 2 times (CAL LED extinguished). 2.002 DISP In the UUT FUNCTION group press the MAN button. 2.002 DISP In the UUT ENTRY keypad press .4, EXC. 2.002 DISP Press MAN in the UUT FUNCTION group. 2.003 DISP In the UUT ENTRY keypad press SFT1, CALA, EXC, SFT1, AC, 2.003 DISP .4, EXC. 2.004 DISP Press CAL SET in the FUNCTION group. 2.005 5700 0.28284V 100H S 2W 2.006 IEEE [@34401]FUNC "VOLT:AC" 2.007 IEEE [@34401]VOLT:AC:RANG:AUTO ON[GTL] 2.008 DISP Adjust the UUT CH 1 GAIN control for a reading 2.009 DISP of 3.5353V. 2.010 DISP Press the CAL button 2 times. 2.011 IEEE [@34401]FUNC "VOLT:AC" 2.012 IEEE [@34401]READ?[I] 2.013 ACC .4000V 0.2312% 2.014 MATH MEM = MEM / 3.535533906 2.015 MATH MEM = .4 * MEM 2.016 MEMC V 1% 3.001 DISP Press the CAL button 2 times (CAL LED extinguished). 3.002 DISP In the UUT FUNCTION group press the MAN button. 3.002 DISP In the UUT ENTRY keypad press .6, EXC. 3.002 DISP Press MAN in the UUT FUNCTION group. 3.003 DISP In the UUT ENTRY keypad press SFT1, CALA, EXC, SFT1, AC, 3.003 DISP .6, EXC. 3.004 DISP Press CAL SET in the FUNCTION group. 3.005 5700 0.42426V 100H S 2W 3.006 IEEE [@34401]FUNC "VOLT:AC" 3.007 IEEE [@34401]VOLT:AC:RANG:AUTO ON[GTL] 3.008 DISP Adjust the UUT CH 1 GAIN control for a reading 3.009 DISP of 3.5353V. 3.010 DISP Press the CAL button 2 times. 3.011 IEEE [@34401]FUNC "VOLT:AC" 3.012 IEEE [@34401]READ?[I] 3.013 ACC .6000V 0.2312% 3.014 MATH MEM = MEM / 3.535533906 3.015 MATH MEM = .6 * MEM 3.016 MEMC V 1% 4.001 DISP Press the CAL button 2 times (CAL LED extinguished). 4.002 DISP In the UUT FUNCTION group press the MAN button. 4.002 DISP In the UUT ENTRY keypad press .8, EXC. 4.002 DISP Press MAN in the UUT FUNCTION group. 4.003 DISP In the UUT ENTRY keypad press SFT1, CALA, EXC, SFT1, AC, 4.003 DISP .8, EXC. 4.004 DISP Press CAL SET in the FUNCTION group. 4.005 5700 0.56568V 100H S 2W 4.006 IEEE [@34401]FUNC "VOLT:AC" 4.007 IEEE [@34401]VOLT:AC:RANG:AUTO ON[GTL] 4.008 DISP Adjust the UUT CH 1 GAIN control for a reading 4.009 DISP of 3.5353V. 4.010 DISP Press the CAL button 2 times. 4.011 IEEE [@34401]FUNC "VOLT:AC" 4.012 IEEE [@34401]READ?[I] 4.013 ACC .8000V 0.2312% 4.014 MATH MEM = MEM / 3.535533906 4.015 MATH MEM = .8 * MEM 4.016 MEMC V 1% 5.001 DISP Press the CAL button 2 times (CAL LED extinguished). 5.002 DISP In the UUT FUNCTION group press the MAN button. 5.002 DISP In the UUT ENTRY keypad press 1, EXC. 5.002 DISP Press MAN in the UUT FUNCTION group. 5.003 DISP In the UUT ENTRY keypad press SFT1, CALA, EXC, SFT1, AC, 5.003 DISP 1, EXC. 5.004 DISP Press CAL SET in the FUNCTION group. 5.005 5700 0.70711V 100H S 2W 5.006 IEEE [@34401]FUNC "VOLT:AC" 5.007 IEEE [@34401]VOLT:AC:RANG:AUTO ON[GTL] 5.008 DISP Adjust the UUT CH 1 GAIN control for a reading 5.009 DISP of 3.5353V. 5.010 DISP Press the CAL button 2 times. 5.011 IEEE [@34401]FUNC "VOLT:AC" 5.012 IEEE [@34401]READ?[I] 5.013 ACC 1.000V 0.2312% 5.014 MATH MEM = MEM / 3.535533906 5.015 MATH MEM = 1 * MEM 5.016 MEMC V 1% 6.001 DISP Press the CAL button 2 times (CAL LED extinguished). 6.002 DISP In the UUT FUNCTION group press the MAN button. 6.002 DISP In the UUT ENTRY keypad press 1.2, EXC. 6.002 DISP Press MAN in the UUT FUNCTION group. 6.003 DISP In the UUT ENTRY keypad press SFT1, CALA, EXC, SFT1, AC, 6.003 DISP 1.2, EXC. 6.004 DISP Press CAL SET in the FUNCTION group. 6.005 5700 0.84853V 100H S 2W 6.006 IEEE [@34401]FUNC "VOLT:AC" 6.007 IEEE [@34401]VOLT:AC:RANG:AUTO ON[GTL] 6.008 DISP Adjust the UUT CH 1 GAIN control for a reading 6.009 DISP of 3.5353V. 6.010 DISP Press the CAL button 2 times. 6.011 IEEE [@34401]FUNC "VOLT:AC" 6.012 IEEE [@34401]READ?[I] 6.013 ACC 1.200V 0.2312% 6.014 MATH MEM = MEM / 3.535533906 6.015 MATH MEM = 1.2 * MEM 6.016 MEMC V 1% 7.001 DISP Press the CAL button 2 times (CAL LED extinguished). 7.002 DISP In the UUT FUNCTION group press the MAN button. 7.002 DISP In the UUT ENTRY keypad press 1.4, EXC. 7.002 DISP Press MAN in the UUT FUNCTION group. 7.003 DISP In the UUT ENTRY keypad press SFT1, CALA, EXC, SFT1, AC, 7.003 DISP 1.4, EXC. 7.004 DISP Press CAL SET in the FUNCTION group. 7.005 5700 0.98995V 100H S 2W 7.006 IEEE [@34401]FUNC "VOLT:AC" 7.007 IEEE [@34401]VOLT:AC:RANG:AUTO ON[GTL] 7.008 DISP Adjust the UUT CH 1 GAIN control for a reading 7.009 DISP of 3.5353V. 7.010 DISP Press the CAL button 2 times. 7.011 IEEE [@34401]FUNC "VOLT:AC" 7.012 IEEE [@34401]READ?[I] 7.013 ACC 1.400V 0.2312% 7.014 MATH MEM = MEM / 3.535533906 7.015 MATH MEM = 1.4 * MEM 7.016 MEMC V 1% 8.001 DISP Press the CAL button 2 times (CAL LED extinguished). 8.002 DISP In the UUT FUNCTION group press the MAN button. 8.002 DISP In the UUT ENTRY keypad press 1.6, EXC. 8.002 DISP Press MAN in the UUT FUNCTION group. 8.003 DISP In the UUT ENTRY keypad press SFT1, CALA, EXC, SFT1, AC, 8.003 DISP 1.6, EXC. 8.004 DISP Press CAL SET in the FUNCTION group. 8.005 5700 1.13137V 100H S 2W 8.006 IEEE [@34401]FUNC "VOLT:AC" 8.007 IEEE [@34401]VOLT:AC:RANG:AUTO ON[GTL] 8.008 DISP Adjust the UUT CH 1 GAIN control for a reading 8.009 DISP of 3.5353V. 8.010 DISP Press the CAL button 2 times. 8.011 IEEE [@34401]FUNC "VOLT:AC" 8.012 IEEE [@34401]READ?[I] 8.013 ACC 1.600V 0.2312% 8.014 MATH MEM = MEM / 3.535533906 8.015 MATH MEM = 1.6 * MEM 8.016 MEMC V 1% 9.001 DISP Press the CAL button 2 times (CAL LED extinguished). 9.002 DISP In the UUT FUNCTION group press the MAN button. 9.002 DISP In the UUT ENTRY keypad press 2, EXC. 9.002 DISP Press MAN in the UUT FUNCTION group. 9.003 DISP In the UUT ENTRY keypad press SFT1, CALA, EXC, SFT1, AC, 9.003 DISP 2, EXC. 9.004 DISP Press CAL SET in the FUNCTION group. 9.005 5700 1.4142V 100H S 2W 9.006 IEEE [@34401]FUNC "VOLT:AC" 9.007 IEEE [@34401]VOLT:AC:RANG:AUTO ON[GTL] 9.008 DISP Adjust the UUT CH 1 GAIN control for a reading 9.009 DISP of 3.5353V. 9.010 DISP Press the CAL button 2 times. 9.011 IEEE [@34401]FUNC "VOLT:AC" 9.012 IEEE [@34401]READ?[I] 9.013 ACC 2.000V 0.2312% 9.014 MATH MEM = MEM / 3.535533906 9.015 MATH MEM = 2 * MEM 9.016 MEMC V 1% 10.001 DISP Press the CAL button 2 times (CAL LED extinguished). 10.002 DISP In the UUT FUNCTION group press the MAN button. 10.002 DISP In the UUT ENTRY keypad press 4, EXC. 10.002 DISP Press MAN in the UUT FUNCTION group. 10.003 DISP In the UUT ENTRY keypad press SFT1, CALA, EXC, SFT1, AC, 10.003 DISP 4, EXC. 10.004 DISP Press CAL SET in the FUNCTION group. 10.005 5700 2.8284V 100H S 2W 10.006 IEEE [@34401]FUNC "VOLT:AC" 10.007 IEEE [@34401]VOLT:AC:RANG:AUTO ON[GTL] 10.008 DISP Adjust the UUT CH 1 GAIN control for a reading 10.009 DISP of 3.5353V. 10.010 DISP Press the CAL button 2 times. 10.011 IEEE [@34401]FUNC "VOLT:AC" 10.012 IEEE [@34401]READ?[I] 10.013 ACC 4.000V 0.2312% 10.014 MATH MEM = MEM / 3.535533906 10.015 MATH MEM = 4 * MEM 10.016 MEMC V 1% 11.001 DISP Press the CAL button 2 times (CAL LED extinguished). 11.002 DISP In the UUT FUNCTION group press the MAN button. 11.002 DISP In the UUT ENTRY keypad press 6, EXC. 11.002 DISP Press MAN in the UUT FUNCTION group. 11.003 DISP In the UUT ENTRY keypad press SFT1, CALA, EXC, SFT1, AC, 11.003 DISP 6, EXC. 11.004 DISP Press CAL SET in the FUNCTION group. 11.005 5700 4.2426V 100H S 2W 11.006 IEEE [@34401]FUNC "VOLT:AC" 11.007 IEEE [@34401]VOLT:AC:RANG:AUTO ON[GTL] 11.008 DISP Adjust the UUT CH 1 GAIN control for a reading 11.009 DISP of 3.5353V. 11.010 DISP Press the CAL button 2 times. 11.011 IEEE [@34401]FUNC "VOLT:AC" 11.012 IEEE [@34401]READ?[I] 11.013 ACC 6.000V 0.2312% 11.014 MATH MEM = MEM / 3.535533906 11.015 MATH MEM = 6 * MEM 11.016 MEMC V 1% 12.001 DISP Press the CAL button 2 times (CAL LED extinguished). 12.002 DISP In the UUT FUNCTION group press the MAN button. 12.002 DISP In the UUT ENTRY keypad press 8, EXC. 12.002 DISP Press MAN in the UUT FUNCTION group. 12.003 DISP In the UUT ENTRY keypad press SFT1, CALA, EXC, SFT1, AC, 12.003 DISP 8, EXC. 12.004 DISP Press CAL SET in the FUNCTION group. 12.005 5700 5.6569V 100H S 2W 12.006 IEEE [@34401]FUNC "VOLT:AC" 12.007 IEEE [@34401]VOLT:AC:RANG:AUTO ON[GTL] 12.008 DISP Adjust the UUT CH 1 GAIN control for a reading 12.009 DISP of 3.5353V. 12.010 DISP Press the CAL button 2 times. 12.011 IEEE [@34401]FUNC "VOLT:AC" 12.012 IEEE [@34401]READ?[I] 12.013 ACC 8.000V 0.2312% 12.014 MATH MEM = MEM / 3.535533906 12.015 MATH MEM = 8 * MEM 12.016 MEMC V 1% 13.001 DISP Press the CAL button 2 times (CAL LED extinguished). 13.002 END